Results for Assays & Kits ( 14523 )
- From: DKK16,283.00
The EZH1 Chemiluminescent Assay Kit is designed to measure activity of the EZH1 complex (EZH1/EED/SUZ12/RbAp48/AEBP) for screening and profiling purposes. The key to the EZH1 Chemiluminescent Assay Kit is a highly specific antibody that recognizes methylated Histone H3K27. With this kit, only three simple steps on a microtiter plate are required for methyltransferase detection. First, Sadenosylmethionine is incubated with a sample containing assay buffer and methyltransferase enzyme for one hour. Next, primary antibody is added. Finally, the plate is treated with an HRPlabeled secondary antibody followed by addition of the HRP substrate to produce chemiluminescence that can then be measured using a chemiluminescence reader.
- From: DKK14,183.00
The PRMT5 TR-FRET Assay Kit is designed to measure PRMT5 activity in a homogeneous 384 reaction format. PRMT5 is a histone methyltransferase that exhibits methylation activity toward H4-R3. This FRET-based assay requires no time-consuming washing steps, making it especially suitable for high throughput screening applications. The key to the PRMT5 TR-FRET Assay Kit is a highly specific antibody that recognizes methylated substrate.
- From: DKK8,093.00
The DOT1L Chemiluminescent Assay Kit is designed to measure DOT1L activity for screening and profiling applications. The key to the DOT1L Chemiluminescent Assay Kit is a highly specific antibody that recognizes methylated K79 residue of H3. With this kit, only three simple steps on a microtiter plate are required for methyltransferase detection. First, S-adenosylmethionine is incubated with a sample containing assay buffer and methyltransferase enzyme for two hours. Next, primary antibody is added. Finally, the strips are treated with an HRP-labeled secondary antibody followed by addition of HRP substrate to produce chemiluminescence that can then be measured using a chemiluminescence reader.
- From: DKK16,283.00
The EZH2 (Y641F) TR-FRET Assay Kit is designed to measure activity of the mutant EZH2 complex (EZH2 (Y641F)/EED/SUZ12/RbAp48/ AEBP) in a homogeneous 384 reaction format. This FRET-based assay requires no timeconsuming washing steps, making it especially suitable for high throughput screening applications. The EZH2 (Y641F) TR-FRET Assay Kit comes in a convenient format, with histone H3 peptide substrate, a Tb-labeled antibody against methylated K27 residue of Histone H3, S-adenosylmethionine, methyltransferase assay buffer, TR-FRET detection buffer, dye-labeled acceptor, and purified EZH2 (Y641F) complex for 384 enzyme reactions. The key to the EZH2 (Y641F) Assay Kit is a highly specific antibody that recognizes methylated Histone H3K27. With this kit, only three simple steps on a microtiter plate are required for methyltransferase detection. First, S-adenosylmethionine is incubated with a sample containing assay buffer and methyltransferase enzyme for 240 minutes. Next, antibody is add
- From: DKK42,180.00
The EZH1 Chemiluminescent Assay Kit is designed to measure activity of the EZH1 complex (EZH1/EED/SUZ12/RbAp48/ AEBP) for screening and profiling purposes. The key to the EZH1 Assay Kit is a highly specific antibody that recognizes methylated Histone H3K27. With this kit, only three simple steps on a microtiter plate are required for methyltransferase detection. First, S-adenosylmethionine is incubated with a sample containing assay buffer and methyltransferase enzyme for two hours. Next, primary antibody is added. Finally, the plate is treated with an HRP-labeled secondary antibody followed by addition of the HRP substrate to produce chemiluminescence that can then be measured using a chemiluminescence reader.
- From: DKK5,940.00
The Kinetic HDAC1 Assay Kit is a complete assay system designed to measure histone deacetylase 1 (HDAC1) activity kinetically for screening and profiling applications. It comes in a convenient 96-well format, with all the reagents necessary for 100 fluorescent HDAC1 activity measurements. In addition, the kit includes purified HDAC1 enzyme and a potent HDAC inhibitor, SAHA, for use as a positive and negative control. The Kinetic HDAC1 Assay Kit is based on a unique fluorogenic substrate and developer combination. This assay method eliminates dealing with the radioactivity, extraction, and chromatography aspects of traditional assays. Using this kit, only one simple step for setting up the HDAC1 reaction on a microtiter plate is needed and then the HDAC1 activity level can be measured kinetically using a fluorescence reader.
- From: DKK5,940.00
The Kinetic HDAC2 Assay Kit is a complete assay system designed to measure histone deacetylase 2 (HDAC2) activity kinetically for screening and profiling applications. It comes in a convenient 96-well format, with all the reagents necessary for 100 fluorescent HDAC2 activity measurements. In addition, the kit includes purified HDAC2 enzyme and a potent HDAC inhibitor, SAHA, for use as a positive and negative control. The Kinetic HDAC2 Assay Kit is based on a unique fluorogenic substrate and developer combination. This assay method eliminates dealing with the radioactivity, extraction, and chromatography aspects of traditional assays. Using this kit, only one simple step for setting up the HDAC2 reaction on a microtiter plate is needed and then the HDAC2 activity level can be measured kinetically using a fluorescence reader.
- From: DKK5,940.00
The Kinetic HDAC3 Assay Kit is a complete assay system designed to measure histone deacetylase 3 (HDAC3) activity kinetically for screening and profiling applications. It comes in a convenient 96-well format, with all the reagents necessary for 100 fluorescent HDAC3 activity measurements. In addition, the kit includes purified HDAC3/NCOR2 enzyme complex and a potent HDAC inhibitor, SAHA, for use as a positive control. The Kinetic HDAC3 Assay Kit is based on a unique fluorogenic substrate and developer combination. This assay method eliminates dealing with the radioactivity, extraction, and chromatography aspects of traditional assays. Using this kit, only one simple step for setting up the HDAC3 reaction on a microtiter plate is needed and then the HDAC3 activity level can be measured kinetically using a fluorescence reader.